Author: Karabekyan, S.
Paper Title Page
TUPDP032 Reference Measurement Methods for Planar and Helical Undulators 575
 
  • S. Karabekyan
    EuXFEL, Schenefeld, Germany
 
  The modern permanent magnet undulators are usually equipped with motors that have integrated feedback electronics. These are essentially rotary encoders that indicate the position of the motor axis. In addition, undulators are also equipped with linear encoders that provide the absolute value of the gap between the magnetic structures or the position of the magnetic girders relative to the undulator frame. The operating conditions of undulators should take into account the risks of failure of electronic equipment under the influence of radiation. In case of encoder failure, the motor or encoder must be replaced. To avoid the need to return the undulator to the magnetic measurement laboratory, reference measurements are required to restore the position of the magnetic structure after replacement. In this article, reference measurement procedures for planar and helical APPLE-X undulators used at the European XFEL are presented.  
poster icon Poster TUPDP032 [1.358 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-ICALEPCS2023-TUPDP032  
About • Received ※ 06 October 2023 — Revised ※ 10 October 2023 — Accepted ※ 14 December 2023 — Issued ※ 17 December 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPDP025 The Superconducting Undulator Control System for the European XFEL 1362
 
  • M. Yakopov, S. Abeghyan, S. Casalbuoni, S. Karabekyan
    EuXFEL, Schenefeld, Germany
  • M.G. Gretenkord, D.P. Pieper
    Beckhoff Automation GmbH, Verl, Germany
  • A. Hobl, A.S. Sendner
    Bilfinger Noell GmbH, Wuerzburg, Germany
 
  The European XFEL development program includes the implementation of an afterburner based on superconducting undulator (SCU) technology for the SASE2 hard X-ray beamline. The design and production of the first SCU prototype, called PRE -SerieS prOtotype (S-PRESSO), together with the required control system, are currently underway. The architecture, key parameters, and detailed description of the functionality of the S-PRESSO control system are discussed in this paper.  
poster icon Poster THPDP025 [2.959 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-ICALEPCS2023-THPDP025  
About • Received ※ 06 October 2023 — Revised ※ 12 October 2023 — Accepted ※ 13 December 2023 — Issued ※ 15 December 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)